Jencor Construction

Fire Safety

Zone 0 Wildfire Rules: What Los Angeles Homeowners Need to Do in the First Five Feet

California approved Zone 0 rules in August 2026 for the first five feet around homes in high fire-risk areas. Here is what they require and how to plan for them.

By Corey Abrams, owner of Jencor Construction, Inc. Published November 14, 2026.

After years of delays, the California Board of Forestry and Fire Protection approved its Zone 0 regulations on August 19, 2026. Zone 0 is the first five feet around a home. Fire investigators have found that this is often where embers land and start the fire that takes a house. The new rules make that strip "ember-resistant," which mostly means keeping things that burn away from the walls.

If you live in the hills of Tarzana, Encino, Brentwood, Bel Air, the Palisades, Topanga, Malibu or Altadena, there's a good chance these rules apply to you.

Who the rules apply to

Zone 0 covers:

  • Homes and other occupied structures in Very High Fire Hazard Severity Zones in areas where cities handle fire protection (Local Responsibility Areas), and
  • Structures anywhere in the State Responsibility Area, whatever the hazard rating.

Homes in moderate or high zones within a city's area aren't covered by the state rule. Your city could still adopt its own. You can look up your address on CAL FIRE's fire hazard severity zone map, or ask your local fire department.

What has to come out of the first five feet

The rules measure five feet out from the exterior walls. They also measure from attached decks, stairs and pergolas. Inside that strip:

  • Remove combustible mulch, wood chips, bark, dead leaves and needles. Gravel, pavers or bare soil work instead.
  • No firewood storage.
  • Clear under decks, balconies, stairs and pergolas of plants and stored items that can burn.
  • Remove dead branches and keep plants away from vents, windows and other openings.
  • Keep roofs and gutters clean, and keep trees trimmed back from the roof and chimney.

Some low, well-watered, non-woody plants may be allowed if they meet the spacing and height rules. Large shrubs and hedges against the house are on their way out.

Fences, gates and sheds

These items have longer deadlines but will cost more to fix:

  • Wood fences and gates can't attach directly to the house. Where a fence meets the structure, the first five feet generally has to be noncombustible, such as a metal section or a masonry pier.
  • Small sheds under 120 square feet can stay in Zone 0 only if they're entirely noncombustible.
  • Existing wood fencing can be repaired, but new combustible fencing isn't allowed in Zone 0.

Deadlines

For existing homes, the requirements phase in over five years:

  • Phase 1 (cleanup, mulch, firewood, gutters, dead vegetation): within about three years.
  • Phase 2 (under-eave areas, gates, fencing, sheds): within five years, with local agencies setting the exact dates.

The timing for new construction has been reported differently by different sources. If you're building new or adding on, plan for Zone 0 from the start and confirm the current requirements with your fire department and plan checker.

One note on insurance: insurers aren't required to give you a discount for complying. Still, Zone 0 work is some of the most effective, least expensive fire hardening you can do.

How to plan for Zone 0 during a remodel or addition

If you're already doing work on the house, it costs less to build Zone 0 in than to retrofit it later:

  • Design hardscape, not planting beds, against the house. A border of pavers, concrete or decomposed granite meets the rule and is easy to maintain.
  • Use metal or masonry where fences and gates meet the house.
  • Choose ember-resistant vents and noncombustible siding, such as stucco or fiber cement, at the base of walls.
  • Think about decks. Keep the space under a deck open and clean, or enclose it with noncombustible materials, and consider noncombustible decking near the house.

In our Primary Suite Addition in Reseda, the new wing sits on a brick paver patio, with fiber cement lap siding down to a concrete foundation. That's the kind of detailing that works well with Zone 0.

Sources

Related reading

Questions

What is Zone 0?

Zone 0 is the ember-resistant zone in the first five feet around a home's exterior walls, attached decks, stairs and pergolas. California's rules require combustible materials such as mulch, firewood and dead vegetation to be removed from that area.

Does Zone 0 apply to my home in Los Angeles?

It applies to homes in Very High Fire Hazard Severity Zones in Local Responsibility Areas and to structures throughout the State Responsibility Area. Check your address on CAL FIRE's fire hazard severity zone map or ask your local fire department.

When do I have to comply with Zone 0?

For existing homes, the first phase of cleanup is due within about three years, and the second phase, which covers fences, gates, sheds and under-eave areas, within five years, with local agencies setting the exact dates.

Will complying with Zone 0 lower my insurance?

Not necessarily. Insurers are not required to give a discount for Zone 0 compliance, though it is one of the most effective ways to reduce ember risk.

Planning a project in Los Angeles? Send Corey a note or call (310) 770-7707. Rules and requirements depend on the specific property; confirm with the city or county before you build.

Tell Corey about your project

Call or send a short note about the property and what you want to build. Corey will call you back to set up a consultation.

Call Text Book a visit